1. Physical Dimensions & Cabinet Cutout Aperture
| Wall / Cabinet Cutout Width | 480 mm |
|---|---|
| Wall / Cabinet Cutout Height | 505 mm |
| Minimum Required Depth | 190 mm |
| Capacity / Output Specification | 3.4 kW Gas / up to 2.0 kW Fanmaster electric |
2. Power, Energy & Operating Ratings
| Fuel / Power Sources | Dual Fuel (Gas convector + 240V Fanmaster blown-air module) |
|---|---|
| Voltage & Element Rating | 240V Fanmaster / 12V fan motor |
| LPG Operating Gas Pressure | 28 mbar Butane / 37 mbar Propane |
| Direct Interchangeability | Truma S3002, Truma Ultraheat (retro-fittable). |
3. Known Common Faults & Diagnostic Guidance
Common UK In-Service Failure Points:
Fanmaster electric control slider PCB burnt out, thermal limit switch trip, blown 12V motor brushes.
Fanmaster electric control slider PCB burnt out, thermal limit switch trip, blown 12V motor brushes.
4. Scotia Yard Teardown & Bench-Testing Standards
Pre-Sale Salvage Verification Procedure:
Test Fanmaster element windings; test 12V auto-fan speed circuit; inspect exhaust heat baffle.
Test Fanmaster element windings; test 12V auto-fan speed circuit; inspect exhaust heat baffle.
Need Spares, Burners, Elements or a Replacement 3600 STC / Trumatic S3002?
Scotia Caravan & Motorhome Salvage tests and stocks second-hand OEM fridges, water heaters, and fires at our Inverurie depot.