Carver & Co. 3600 STC / Trumatic S3002

Space Heater / Blown Air • Production Era: 1992–2002 • Verified Workshop Reference

1. Physical Dimensions & Cabinet Cutout Aperture

Wall / Cabinet Cutout Width480 mm
Wall / Cabinet Cutout Height505 mm
Minimum Required Depth190 mm
Capacity / Output Specification3.4 kW Gas / up to 2.0 kW Fanmaster electric

2. Power, Energy & Operating Ratings

Fuel / Power SourcesDual Fuel (Gas convector + 240V Fanmaster blown-air module)
Voltage & Element Rating240V Fanmaster / 12V fan motor
LPG Operating Gas Pressure28 mbar Butane / 37 mbar Propane
Direct InterchangeabilityTruma S3002, Truma Ultraheat (retro-fittable).

3. Known Common Faults & Diagnostic Guidance

Common UK In-Service Failure Points:
Fanmaster electric control slider PCB burnt out, thermal limit switch trip, blown 12V motor brushes.

4. Scotia Yard Teardown & Bench-Testing Standards

Pre-Sale Salvage Verification Procedure:
Test Fanmaster element windings; test 12V auto-fan speed circuit; inspect exhaust heat baffle.